What was found
DURING SCHEDULED INSPECTION AT AERO CORP IN LAKE CITY, FL, FOUND CORROSION ON THE UPPER CAP OF THE FLOOR BEAM STA 965, LBL 48. RECEIVED FROM AERO SUPPLY L-ANGLE NR 635060. FIT, TRIMMED, DRILLED UP, DEBURRED ANGLE IAW DC9 SRM 53-11-3 FIG 11A, SRM 51-10-4. TREATED AND PRIMED IAW DC9 SRM 51-10-3. INSTALLATION TO BE COMPLETED ON W/O NR 59881. (X)