What was found
DURING A SCHEDULED INSPECTION AT AERO CORP IN THE AFT CARGO AREA, CORROSION ALONG THE INTERCOSTAL BETWEEN STATION 850-890, STRINGER 29R. MECHANICALLY REMOVED CORROSION IAW DC-9 SRM 51-10-3 .003 MATERIAL, CHECKED WITH DME A1244, WITHIN LIMITS IAW DC-9 SRM 53-04 FIG 38 TREATED AND PRIMED IAW DC-9 SRM 51-10-3 AT AFT CARGO COMP ALONG INTERCOSTAL BETWEEN STATION 850 AND 890 AT STRINGER 28R. (M)