What was found
UPON REMOVAL OF MANHOLE COVER, RIB 2 RIGHT WING SEVERAL BOLTS WOULD NOT REMOVE UPON DRILLING BOLTS OUT, DRILL OUT OF AILIGNMENT ON 3 BOLTS CAUSED ELONGATION 3 HOLES RIB 2. DRILLED HOLES A, B, AND C TO ACCOMMODATE BUSHINGS, MANUFACTURED BUSHINGS FROM 7075-T61. INSTALLED BUSHINGS PER FAXES AVOR JM/RJ00 45-97 AND DJR/RJ0055-97 ON RIB 2 RIGH WING.