What was found
DURING AN SCHEDULED INSPECTION AT AERO CORP, THE FOLLOWING WAS FOUND; IN THE FORWARD LOWER CARGO PIT AT BS 480 BL 22 RIGHT, THERE IS AN AREA OF CORROSION UNDER THE TRANSITION PANEL. FORMED ANGLE FROM 7075-0 .063 23 INCH BY 2.75 INCH BY 1.25 INCH. INSTALLED IAW SRM 51-30-2, 51-10-1, 51-40-3, 51-10-2 AND MM 51-21-21.