What was found
DURING AN SCHEDULED INSPECTION AT AERO CORP, THE FOLLOWING WAS FOUND; IN THE FORWARD LOWER CARGO PIT AT BS 460 BL 22 RIGHT, THERE IS AN AREA OF CORROSION UNDER THE TRANSITION PANEL. FORMED ANGLE FROM 7075-0 .063 14.875 INCH BY 1 INCH BY 1.25 INCH. DEBURRED AND COUNTERSUNK IAW SRM 51-40-3.