What was found
AFT CARGO FLOOR ATTACH ANGLE NR 6 CORROSION THROUGH OUT. CUT OUT CORRODED SECTION OF ANGLE AND FABRICATED REPAIR ANGLE FROM 7075 T-6 511 L-ANGLE EXTRUSION .080 INCH BY 1 INCH BY 1 INCH BY 9 INCH. DRILLED, DEBURRED, COUNTERSUNK IAW B737 SRM 51-10-05, 51-10-7, 51-30-8. TREATED, PRIMED, IAW B737 SRM 51-10-02.