What was found
31J - THE FOLLOWING WAS FOUND, MAIN CABIN, STATION 986 LBL 0-12 FLOORBEAM CORRODED. FABRICATED NEW T-ANGLE. FABRICATED TWO STRAPS FROM 7075 T6 .063 10.75 INCH BY 1 INCH AND 9.2 INCH BY 1 INCH. FABRICATED TWO STRAPS FROM 7075 T6 .071 13.5 INCH BY 1 INCH. FABRICATED TWO L-ANGLES FROM 7075T6 .063 10 INCH BY 1.75 INCH BY 1 INCH AND 11 INCH BY 1.75 INCH BY 1 INCH. FAB TWO L-ANGLES FROM 7075 T6 .071 13.5 INCH BY 1.75 INCH BY 1 INCH. INSTALLED REPAIR IAW SRM 53-109, 51-10-2 AND MM 51-21-21. N/R NR 70560/0369.