What was found
31J - THE FOLLOWING WAS FOUND, CABIN FLOORBEAM STATION 328 BL '0' 60 HAS CORROSION. FABRICATED NEW FLOORBEAM FROM BAC 1505-100246 15.5 BY 2 INCH IAW SRM 51-101. FABRICATED T-CAP FROM 7075 T6511 2.25 INCH BY 3 INCH BY 60 INCH AND 1.25 INCH BY 2.25 INCH BY 60 IAW SRM 53-10-9. FABRICATED FOUR ANGLES FROM 7075-0 .063 24 INCH BY 4 INCH IAW SRM 53-10-9. INSTALLED ALL REPAIRS IAW SRM 53-10-9. N/R NR 71087/0698.