SDR 97ZZZM695

Service difficulty report · Fault Transformr · Swrngn SA227AC

Difficulty date
May 30, 1997
Submitted
March 26, 2000
Operation
Air carrier
Aircraft
N158MC
Make and model
Swrngn SA227AC
Aircraft serial
AC726B
Part
Fault Transformr
Part number
BC66
Condition
Failed
Location
Rt Battery
Stage of operation
CL
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

FLT 2931 - OUTBOUND OF MSP, BATTERY FAULT LIGHT AND BOTH RIGHT AND LEFT DISCONNECT LIGHTS ILLUMINATED. CREW FOLLOWED QUICK REFERENCE HANDBOOK AND COULD NOT RESET. AIR TURNBACK TO MSP. MAINTENANCE REPLACED RIGHT BATTERY FAULT TRANSFORMER AND THE SERIES PARALLEL RELAY. COMPLETED GROUND RUNS. OPS CHECK GOOD. (M)