What was found
ENGINE FLAME-OUT ON SHORT FINAL. REPLACED FUEL PUMP WITH OVERHAULED UNIT, FUEL CONTROL WITH SERVICEABLE UNITS, P2T2 SENSOR WITH NEW. GROUND RUN, FLAME OUT CHECK, PERFORMANCE RUN, AND LEAK CHECK CARRIED OUT SATISFACTORILY.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ENGINE FLAME-OUT ON SHORT FINAL. REPLACED FUEL PUMP WITH OVERHAULED UNIT, FUEL CONTROL WITH SERVICEABLE UNITS, P2T2 SENSOR WITH NEW. GROUND RUN, FLAME OUT CHECK, PERFORMANCE RUN, AND LEAK CHECK CARRIED OUT SATISFACTORILY.