What was found
DURING A SCHEDULED INSPECTION AT AERO CORP, CORROSION WAS FOUND ON THE SUB-FLOOR BETWEEN STA 130 AND STA 140 BL 13R. REMOVED CORRODED AREA, FABBED UP DOUBLER AND FILLER IAW DC9 SRM 51-10-4. ALODINED AND PRIMED IAW DC9 SRM 51-10-3. INSTALLED DOUBLER AND FILLER IAW DC9 SRM 51-30-2. (MATERIAL DIMENSIONS 28.75 INCHES BY 2.75 INCHES, 2 EACH.)