SDR 97ZZZX3067

Service difficulty report · Pump · Dorner DO328100

Difficulty date
June 16, 1997
Submitted
March 26, 2000
Operation
General aviation
Aircraft
N653PC
Make and model
Dorner DO328100
Aircraft serial
3027
Part
Pump
Part number
42086
Condition
Failed
Location
Hydra System
Part time
1,570 hours
Component
Abex
Stage of operation
AP
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

INBOUND, MAIN HYDRA PUMP FAILED. MADE NORMAL LANDING WITH BACK-UP AUXILIARY PUMP. INSPECTED MOTOR PUMP ASSY, FOUND POWER BREAKERS TRIPPED. RESET AND OPS CHECKED SYSTEM, BREAKERS TRIPPED, UNIT REMOVED. INSTALLED REPAIRED UNIT. OPS CHECK WAS GOOD. AIRCRAFT RETURNED TO SERVICE. NOTE: MAIN HYDRA SYSTEM IS 115 VAC MOTOR PUMP ASSY DRIVEN BY ENGINE ALTERNATORS.