What was found
DURING ANNUAL INSPECTION, FUEL WAS SHUT OFF FOR CLEANING CARBURETOR, DRAIN, AND GASCULATOR. UPON TURNING FUEL ON, FUEL LEAKED FROM HOSE IN A STEADY STREAM. HOSE WAS LOCATED ON LOW PRESSURE SIDE FEEDING ENGINE DRIVEN PUMP. HOSE WAS ALSO IN A LOCATION WHERE IT WAS NOT AGITATED BY THE PREVENTATIVE MAINTENANCE. SUBMITTER STATED THIS IS THE SECOND DEUTSCH HOSE FAILURE ON THIS AIRCRAFT WITH LOW TIME.