What was found
CORROSION (C53-107-01) ON UPPER TEE CHORD TOP AND UNDERSIDE AND IN NUTPLATE HOLES IN FLOOR BEAM BS 1006, LBL 10 - LBL 29, WL 208. REMOVED CORROSION BS 1006, LBL 10 - LBL 29 , WL 208. .013 INCH MATERIAL LOSS FROM ORIGINAL MATERIAL OF .135 INCH, FOUND TO BE WITHIN LIMITS PER SRM 53-60-51. TREATED AREA PER SRM 51-20-01.