CORROSION (C53-107-01) ON FLOOR BEAM STA 706 RBL 48 LBL 208. REMOVED CORROSION. MAX REMOVED .009 INCH FROM ORIGINAL .112 INCH WITHIN LIMITS PER SRM 53-60-13.