What was found
ANNUAL INSPECTION FOUND ELEVATOR AND AILERONS OUT OF BALANCE DUE TO RECENT PAINT JOB. UNITS HAD NOT BEEN STRIPPED PRIOR TO PAINTING OR CHECKED FOR BALANCE. NO REFERENCE TO AD 87-02-02 OR AD 94-20-04 WAS FOUND IN RECORDS.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ANNUAL INSPECTION FOUND ELEVATOR AND AILERONS OUT OF BALANCE DUE TO RECENT PAINT JOB. UNITS HAD NOT BEEN STRIPPED PRIOR TO PAINTING OR CHECKED FOR BALANCE. NO REFERENCE TO AD 87-02-02 OR AD 94-20-04 WAS FOUND IN RECORDS.