SDR 97ZZZX4462

Service difficulty report · Inverter · Gulstm G1159A

Difficulty date
September 29, 1997
Submitted
March 26, 2000
Operation
General aviation
Aircraft
N843HS
Make and model
Gulstm G1159A
Aircraft serial
496
Part
Inverter
Part number
10090910104
Condition
Failed
Location
Iru Nr 2 Fan
Part time
2,345 hours
Stage of operation
IN
Nature of condition
B
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

DURING PRE-DEPARTURE CHECK OF AIRCRAFT, A BURNING ODOR WAS DETECTED IN AFT BAGGAGE AREA. UPON CLOSER INSPECTION, SMOKE NOTED COMING FROM BENEATH THE HAT SHELF. POWER WAS REMOVED AND THE NR 2 HG-1075 INERTIAL REFERENCE UNIT WAS REMOVED. THE IRU FAN INVERTER WAS FOUND TO BE THE SOURCE OF THE SMOKE. INSTALLED HONEYWELL DC BLOWER KIT, PN 26012423-105, IN ALL 3 IRU'S AND RETURNED AIRCRAFT TO SERVICE.