SDR 97ZZZX4495

Service difficulty report · Relay · Bolkms BK117B1

Difficulty date
September 12, 1997
Submitted
March 26, 2000
Operation
Air carrier
Aircraft
N5194C
Make and model
Bolkms BK117B1
Aircraft serial
7169
Part
Relay
Part number
MS24178D1
Condition
Wire Shorted
Location
Main Emerg Pwr
Stage of operation
CR
Nature of condition
M, B
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

PRIOR TO FLIGHT, BATTERY SWITCH WOULD NOT WORK. T/S MX FOUND THE MAIN EMERG PWR RELAY HAD PREVIOUSLY CAUGHT FIRE. PORTIONS OF RELAY WERE MELTED AND EVIDENCE OF FLAMES APPROX 18 INCHES HIGH ABOVE RELAY. ACFT CONFIGURED WITH STC SH498NE 'AFT BATTERY INSTALLATION' WHICH RELOCATES RELAY FROM THE NOSE AREA TO RT SIDE SHELL OF CABIN AREA. NEVER ANY REPORT OF FIRE OR SMELL OF SMOKE REPORTED. INVEST BY MECH REVEALED ONE OF THE WIRES WHICH ENERGIZES COIL OF MAIN EMERG POWER RELAY HAD BROKEN OFF AT TERMINAL END WHERE IT CONNECTED TO ANOTHER COMPONENT. BROKEN WIRE HAD CONTACTED GROUND.