What was found
BLADE WAS RECEIVED FOR A MAJOR INSPECTION. DURING DYE CHECK OF THE BLADE SHANK AS REQUIRED DURING MI, TWO LINEAR INDICATIONS WERE FOUND AND VERIFIED WITH FLUORESCENT PENETRANT INSPECTION. BOTH INDICATIONS WERE ON THE BLADE PIN BOSS AREA. ONE IS ON THE THRUST WASHER SURFACE AND IS APPROXIMATELY .1875 INCH IN LENGTH. THE OTHER INDICATION IS JUST BELOW THE THRUST WASHER SURFACE AND IS APPROXIMATELY .2187 INCH IN LENGTH. THESE INDICATIONS ARE LOCATED APPROXIMATELY 90 DEGREES IN RESPECT TO EACH OTHER.