What was found
DURING OVERHAUL OF ESCAPE SLIDE ASSEMBLY FOUND DISCHARGE VALVE MISSING ITS BALL SPRING P/N 504S0023. CAUSE FOR CONDITION IS DUE TO ASSEMBLY ERROR DURING LAST OVERHAUL OR VALVE SERVICING. CONDITION AS STATED COULD HAVE RESULTED IN LOSS OF STORED GASSES FROM SLIDE'S INFLATION BOTTLE AND/OR HAD THE POTENTIAL FOR AN UNCOMMANDED INFLATION OF THE ESCAPE SLIDE ASSEMBLY. SUBMITTED BY B. F. GOODRICH AES SEATTLE SERVICE CENTER, REPAIR STATION NR ET3D487L. ADDITIONAL DETAILS, SKETCHES, DRAWINGS OR COMPONENT OVERHAUL MANUAL SPECIFICATIONS ARE AVAILABLE UPON REQUEST. BFG REF SO NR 201293.