What was found
'PLAY' WAS NOTED BETWEEN THE ELEVATORS. INSPECTION FOUND ELEVATOR PINS TO TORUQE TUBE WORN. REAMING, PER SM, DID NOT REMOVE ALL THE PLAY. REPLACED TORQUE T UBE ASSY WITH NEW PINS. THERE WAS NO ABNORMAL FLIGHT CONDITIONS BEFORE OR AFTER. TORQUE TUBE INSPECTION IS REQUIRED EACH 1,000 HOURS, 126.6 HOURS SINCE LAST PRIMARY INSPECTION.