What was found
DURING LINE MAINTENANCE INSPECTION, FOUND EMERGENCY ESCAPE PATH LIGHTING BETWEEN SEATS 18 THRU 21 AND AT LEFT LAVATORY EXIT INOPERATIVE. REPLACED POWER SUPPLY AND BATTERIES, OPERATIONAL CHECK NORMAL.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING LINE MAINTENANCE INSPECTION, FOUND EMERGENCY ESCAPE PATH LIGHTING BETWEEN SEATS 18 THRU 21 AND AT LEFT LAVATORY EXIT INOPERATIVE. REPLACED POWER SUPPLY AND BATTERIES, OPERATIONAL CHECK NORMAL.