What was found
DURING APPROACH INTO CLT, LANDING GEAR WARNING HORN SOUNDED FOR APPROXIMATELY TWO SECONDS WITH NOSE GEAR GREEN LIGHT OFF AND RED UNSAFE LIGHT ON. CREW RECYCLED GEAR AND RECEIVED NORMAL INDICATIONS. AIRCRAFT LANDED WITHOUT INCIDENT. MAINTENANCE REPORTED PSEU FAULT OF NLG LOCKED PROX SENS OPEN. REPLACED NOSE GEAR WIRING HARNESS. OPERATIONAL CHECK NORMAL ON GEAR SWING.