What was found
DURING APPROACH, NOSE LANDING GEAR UNSAFE LIGHT REMAINED ON AFTER GEAR EXTENSION. EMERGENCY GEAR EXTENSION PROCEDURES WERE UTILIZED AND FLIGHT WAS DIVERTED TO ORD. AIRCRAFT LANDED WITHOUT INCIDENT. MAINTENANCE FOUND NOSE GEAR DOWNLOCK PROXIMITY SENSOR BROKEN. REPLACED SENSOR, OPERATIONAL CHECK NORMAL.