What was found
NR 0221 BS 720B PLUS 5, STRINGER 15R END CRACKED AT HI-LOK FWD OF WING SCANNING LIGHT. CUT END OF STR HFEC CHECKED CUT EDGE OF STRINGER. FABRICATED U-CHANNEL OF .040 7075-T6 AND FILLERS. INSTALLED REPAIR IAW SRM 53-10-3 FIG 5.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.