What was found
WHILE WORKING NR 0842, FOUND CORROSION ON STRINGER 1, BS 520 TO 740. *S/D* REMOVED CORROSION ON STRINGER, EVALUATED DAMAGE. REMOVED 2 DAMAGED SECTIONS AND INSTALLED 2 NEW SECTIONS OF STRINGER AT STR 1, BS 440 TO 570 AND BS 650 TO 740 IAW FED-EX SRM 53-10-3 FIG 3.