What was found
BELTFRAME DAMAGED BS 520, RT SIDE 6 INCHES ABOVE FLOORBEAM. TRIMMED OUT DAMAGE. INSTALLED TYPICAL FORMED SECTION REPAIR PER SRM 51-40-3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BELTFRAME DAMAGED BS 520, RT SIDE 6 INCHES ABOVE FLOORBEAM. TRIMMED OUT DAMAGE. INSTALLED TYPICAL FORMED SECTION REPAIR PER SRM 51-40-3.