What was found
FORWARD FUSELAGE PLATE, VENT CASE ATTACH FLOOR SHOW LEVEL 2 CORROSION FROM STATION 360 TO STATION 400. REMOVED AND REPLACED PLATE AT AFFECTED AREA AS PER SRM 51-13-1. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FORWARD FUSELAGE PLATE, VENT CASE ATTACH FLOOR SHOW LEVEL 2 CORROSION FROM STATION 360 TO STATION 400. REMOVED AND REPLACED PLATE AT AFFECTED AREA AS PER SRM 51-13-1. (M)