What was found
DURING AN ANNUAL INSPECTION, HORIZ STAB MOVED UP AND DOWN FROM THE RT SIDE. AN EXCESSIVE AMOUNT OF MOVEMENT WAS NOTED. DUIRNG CLOSER INSPECTION, FOUND BOLT, P/N NAS1306-4, MISSING FROM THE RT FORWARD ATTACH POINT. INSIDE THE STABILIZER AFT OF THE FORWARD SPAR, BOLT WAS FOUND. FORWARD OF THE AFT SPAR IN THE AFT TAILCONE, FOUND 2 HALVES OF NUT, P/N MS21044N6.