SDR 98ZZZX1480

Service difficulty report · Tunnel Cap

Difficulty date
February 20, 1998
Submitted
March 26, 2000
Operation
General aviation
Part
Tunnel Cap
Part number
6A0129001
Condition
Defective
Location
Float
Component
Wiplineinc · 6000
Stage of operation
IN
Nature of condition
W
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

NEW PART MADE FROM A MACHINED ALUMINUM BLOCK WAS INSPECTED BEFORE INSTALLATION. A VOID SURFACE WAS FOUND ON ONE FACE WITH PITTING ON THE OTHER SIDE IN SAME LOCATION. THE ANODIZING DID NOT APPEAR TO HAVE TAKEN IN THE VOID. THIS PART IS IN A MOIST ENVIRONMENT, OFTEN SALTWATER, AND WOULD HAVE CORRODED THROUGH QUICKLY. IT APPEARS DEFECT WAS PRESENT IN ORIGINAL BLOCK OF ALUMINUM BEFORE MACHINING. RETURNED PART TO WIPLINE FOR REPLACEMENT.