What was found
INSPECTION FOUND BOTH MAGNETO HOUSINGS ARE CRACKED IN SEVERAL PLACES. SUSPECT THAT WHEN NEW COILS WERE INSTALLED, THE WEDGES WERE INSTALLED INCORRECTLY OR OVERDRIVEN INTO POSITION.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND BOTH MAGNETO HOUSINGS ARE CRACKED IN SEVERAL PLACES. SUSPECT THAT WHEN NEW COILS WERE INSTALLED, THE WEDGES WERE INSTALLED INCORRECTLY OR OVERDRIVEN INTO POSITION.