SDR 98ZZZX2350

Service difficulty report · Insulator · Semco CHALLENGER

Difficulty date
May 22, 1998
Submitted
March 26, 2000
Operation
General aviation
Make and model
Semco CHALLENGER
Part
Insulator
Part number
43772
Condition
Shorted
Location
Power Supply
Stage of operation
IN
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

POWER SUPPLY S/N'S 057R, 116R, 139R, 173R, 259R, AND 328R FOUND Q5 DAMAGED BY SHORT-CIRCUIT (S/N 173R). INSPECTION REVEALED MICA INSULATOR MIS-POSITIONED UNDER Q5 PERMITTING COLLECTOR TO SHORT TO CHASSIS (GROUND). INSPECTION OF ADJACENT COMPONENTS (CR19 AND Q6) REVEALED SAME CONDITION ALTHOUGH NO SHORT-CIRCUITS, YET. INSP OF REMAINING 5 UNITS REVEALED SAME CONDITION, ALTHOUGH NO SHORT-CIRCUITS, YET. IT IS UNKNOWN WHETHER THESE COMPONENTS (Q5, Q6, CR19) OR RESPECTIVE INSULATORS ARE ORIGINAL (FACTORY) OR ARE IN-SERVICE REPLACEMENTS. SUBMITTER RECOMMENDED MORE CARE BE GIVEN TO PROPER PLACEMENT OF MICA INSULATORS UNDER COMPONENTS.