What was found
INBOUND TO SHORE BASE, COPILOT'S UPPER 'GREENHOUSE' WINDOW BROKE AND A PORTION OF IT DEPARTED AIRCRAFT. NO PREVIOUS DEFECTS OR REPAIRS PRIOR TO INCIDENT. MAINTENANCE REPLACED WINDOW ASSEMBLY. REF: 214ST IPC, CHAPTER 52-99-00, FIGURE 52-2, ITEM NR 9.