What was found
EVACUATION SLIDE RECEIVED PACKED WITH SHEAR PIN RESTRAINTS INSTALLED. RECEIVING INSPECTION REVEALED THE SHEAR PIN RESTRAINTS WERE PREVIOUSLY ACTIVATED. THE TWO HALVES OF THE SHEAR PIN RESTRAINTS WERE RE-ATTACHED WING STEEL SAFETY WIRE. ONCE SHEAR PIN RESTRAINTS ARE ACTIVATED AND BROKEN DURING A SLIDE DEPLOYMENT, EACH SHEAR PIN RESTRAINT MUST BE REPLACED WITH NEW. SHEAR PIN RESTRAINTS ARE DESIGNED TO BREAK AT A PRESCRIBED LOAD. FAILURE TO BREAK AT THE REQUIRED LOAD CAN CAUSE THE EVACUATION SLIDE TO DEPLOY IMPROPERLY AND POSSIBLY CAUSE THE SLIDE TO MALFUNCTION DURING AN ACTUAL EMERGENCY.