As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING C-CHECK INSPECTION, WINDSHIELD CENTER POST ATTACH SUPPORT FITTINGS ARE INSPECTION IAW ASA EO-120-53-0021. THE UPPER SUPPORT FITTING WAS FOUND CRACKED ON THE LEFT SUPPORT LEG IN THE RADIUS. THE CRACK WAS DETECTED BY VISUAL INSPECTION. CRACK RUNS FROM BACK OF LEG FORWARD .75 INCH.