SDR 98ZZZX4550

Service difficulty report · Indicator

Difficulty date
September 23, 1998
Submitted
March 26, 2000
Operation
General aviation
Engine
Lyc LTS101650B1
Part
Indicator
Part number
430118501
Condition
Erratic
Location
Cockpit
Part time
1,875 hours
Stage of operation
CR
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) PILOT NOTED NEEDLE MOVEMENT ON OIL PRESSURE GAUGE. WET LINE MAINTENANCE CHECK REVEALED FLUCTUATIONS IN EXCESS OF 5 PSI LIMIT. UNABLE TO ADJUST OUT PER THE MAINTENANCE MANUAL.