What was found
REMOVED ELEVATOR DOWN SPRING TO FACILITATE OTHER MAINTENANCE. DISCOVERED THE ELEVATOR DOWN SPRING DRAW BOLT EXCESSIVELY WORN NEAR FORWARD MOUNT BOLT. TO PREVENT MISSING THIS ITEM DURING THE B6 INSPECTION, THE INSPECTION ITEM SHOULD READ: CHECK ELEVATOR DOWN SPRING DRAW BAR FOR WEAR, PAYING PARTICULAR ATTENTION NEAR THE FORWARD ATTACH POINT. FAILURE OF THIS PART COULD CAUSE DAMAGE TO EQUIPMENT OF FAILURE OF THE ELEVATOR FLIGHT CONTROLS.