SDR 98ZZZX4796

Service difficulty report · Pump · Piper PA24250

Difficulty date
December 9, 1998
Submitted
March 26, 2000
Operation
General aviation
Aircraft
N7145P
Make and model
Piper PA24250
Aircraft serial
242310
Part
Pump
Part number
211CC
Condition
Failed
Location
Vacuum System
Part time
37 hours
Component
Airborne
Stage of operation
CR
Nature of condition
O
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

SHAFT FAILED. UPON INSPECTING PUMP INTERNALLY, CORE WAS BROKEN IN 3 PIECES. OCCURRED IN CRUISE FLIGHT. VACUUM GAUGE HAD INTERMITTENT FLICKER.

More about the Piper PA-24-250