SDR 9905129983

Service difficulty report · Controller · Doug DC932

Difficulty date
November 25, 1999
Submitted
March 26, 2000
Operation
Air carrier
Aircraft
N983US
Make and model
Doug DC932
Aircraft serial
45790
Part
Controller
Part number
60714621
Condition
Failed
Location
Cabin Temp
Part time
62,522 hours
Stage of operation
CL
Nature of condition
B, J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AFTER TAKEOFF FROM MSP, CABIN TEMPERATURE WAS 150 DEGREES AND ACCOMPANIED BY SMOKE AND FUMES. THE RIGHT SIDE AUTOMATIC CABIN TEMPERATURE CONTROL VALVE WAS AT FULL HOT. FLIGHT CREW DISABLED AUTO TEMPERATURE CONTROL SYSTEM PER MAINTENANCE CONTROL AND CONTINUED MEL 21-03A. AIRCRAFT RETURNED TO MSP WITHOUT INCIDENT. MAINTENANCE REPLACED THE RIGHT AUTO TEMPERATURE CONTROLLER. OPERATIONAL CHECK GOOD AND REMOVED FROM MEL. AIRCRAFT RETURNED TO SERVICE.

More about the Doug DC-9-32