What was found
99-157 - AFT T/O CARGO FIRE IND AT POS 4/5. POS 5 LIGHT STEADY 4 WAS INTERMITTENT. BLEW SENSING LINES FROM ALL 6 SMOKE DETECTORS BACK INTO CABIN. CLEANED CANNON PLUGS ON DETECTORS. SMOKE DETECTION TEST NORM IAW MM 26-16-001-5.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
99-157 - AFT T/O CARGO FIRE IND AT POS 4/5. POS 5 LIGHT STEADY 4 WAS INTERMITTENT. BLEW SENSING LINES FROM ALL 6 SMOKE DETECTORS BACK INTO CABIN. CLEANED CANNON PLUGS ON DETECTORS. SMOKE DETECTION TEST NORM IAW MM 26-16-001-5.