As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
COMPLETE 'A' SYS HYD LOSS. GEAR CRANKED NORM AND ALT FLAPS OPER NORM. FOUND RT ELEV PWR CONTROL UNIT FIT BUSTED. REMOVED RT PWR CONTROL UNIT PER 727-200 MM 27-30-81. PWR CONTROL UNIT NEEDS INSTALL AND OPER CK. REMOVED AND REPLACED RIGHT ELEV PWR CONTROL PACK PER MM 27-30-081-4, OPER CK.