What was found
FLAPS STUCK AT APPROX 2 DEG WITH THE FLAP SYS NR 1 AND NR 2 FLAP FAULT LIGHTS ILLUM ON O/H PAN'L AND ECAM MSG NR 1 AND NR 2 FLAP FAULT. *S/D* REMOVED AND REPLACED NR 1 AND NR 2 SFCC'S, FLAPS HANDLE CSU, AND NR 4 LEFT FLAP JACKSCREW. OPS CHECK OK.