What was found
MAIN CARGO DOOR, UPPER JAM INSTALLATION CLIPS MISSING 2 EACH. FABRICATED CLIPS AND INSTALLED IAW DWG AS11035 AND DC-8 SRM 51-1-8. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN CARGO DOOR, UPPER JAM INSTALLATION CLIPS MISSING 2 EACH. FABRICATED CLIPS AND INSTALLED IAW DWG AS11035 AND DC-8 SRM 51-1-8. (M)