As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FOUND CORROSION FRAME UPPER AND LOWER CHORDS AND WEB AREA FRAME 1280, L34R-L31L. REMOVED CORROSION IAW DC-8 SRM 51-1-8. FABRICATED DOUBLER IAW DC-8 SRM 51-1-21 SIZE 3 INCH BY 12 INCH AND INSTALLED IAW DC-8 SRM 51-1-21. WELDED FRAME FLOOR SUPPORT PER EO 99-061. (M)