What was found
FOUND DURING D-CHECK, HOLE MISDRILLED INSIDE LEFT CENTER TANK AT XCW 69.5 UPPER SURFACE, FUSELAGE STATION 761. BLENDED OUT DRILL START, SPOT FACED. TREATED AND PRIMED. INSTALLED FACTORY FASTENER. IT IS ACCEPTABLE TO RETURN TO SERVICE PER EO NR 99-186 WITH APPROVED 8110-3 DATED 11/12/99. (M)