What was found
FOUND DURING D-CHECK, EXTERIOR STATION 1382, L36 OVERBOARD DRAIN BROKEN. FABRICATED EXTERNAL DOUBLER AND INSTALLED DRAIN FITTING PER EO NR 99-186 WITH APPROVED 8110-3 DATED 12/09/99. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND DURING D-CHECK, EXTERIOR STATION 1382, L36 OVERBOARD DRAIN BROKEN. FABRICATED EXTERNAL DOUBLER AND INSTALLED DRAIN FITTING PER EO NR 99-186 WITH APPROVED 8110-3 DATED 12/09/99. (M)