What was found
AT APPROXIMATELY BODY STATION 322, THERE EXISTS A CRACK IN THE 141U8007-502 INTERCOSTAL. THE CRACK EXISTS IN THE LOWER HORIZONTAL FLANGE AND EXTENDS TO THE SECOND FASTENER HOLE COMMON TO THE 141U8007-501 SPLICE. *S/D* 141U8007-502 TRIMMED OUT AROUND CRACKED AREA. 141U8007-501 SPLICE STRAP EXTENDED TO PICK UP ADDITIONAL FASTENERS BEYOND CRACKED AREA. PART ROUTED TO BAC FOR ANALYSIS.