What was found
DURING CRUISE (FROM M-92 FERRY PERMIT) TANK 1 WAS INCREASING 100 LBS EVERY 38 SECONDS WITH 2L PUMPS ON. REMOVED DEBRIS FROM NR 1 TANK BOOST PUMP HOUSING BYPASS CHECK VALVE PER (F1M-28-24600 FIG 112) VERIFIED 0 FUEL TRANSFER. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING CRUISE (FROM M-92 FERRY PERMIT) TANK 1 WAS INCREASING 100 LBS EVERY 38 SECONDS WITH 2L PUMPS ON. REMOVED DEBRIS FROM NR 1 TANK BOOST PUMP HOUSING BYPASS CHECK VALVE PER (F1M-28-24600 FIG 112) VERIFIED 0 FUEL TRANSFER. (M)