What was found
DURING PREFLIGHT, FOUND FORWARD SECTION OF EMERGENCY FLOOR PATH LIGHTING INOPERATIVE. REPAIRED CHAFED WIRE AT R1 DOOR FLOOR EMERGENCY EXIT LIGHT IAW WIRING DIAGRAM 33-51-03. OPS CHECKED GOOD. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING PREFLIGHT, FOUND FORWARD SECTION OF EMERGENCY FLOOR PATH LIGHTING INOPERATIVE. REPAIRED CHAFED WIRE AT R1 DOOR FLOOR EMERGENCY EXIT LIGHT IAW WIRING DIAGRAM 33-51-03. OPS CHECKED GOOD. (M)