What was found
DURNIG A CPCP 4 INSPECTION PERFORMED AT AMR EAGLE MAINTENANCE CENTER, FOUND THE RIGHT AFT OUTBOARD SEAT TRACK CORRODED. INSTALLED NEW SEAT TRACK AS PER SRM 51-25-04 AND EO NR E9-5300-013R2. CAUSE OF DAMAGE, ENVIRONMENTAL, LAVATORY/GALLEY SPILLS. (M)